Pro-Leaf CO2 Generators
Enrich areas of up to 220m2 with CO2 - grab a Pro-Leaf CO2 Generator.
It burns liquid propane gas (LPG) to produce CO2 + water vapour.
They're super flexible - you can modify your CO2 output with ease. To do this, you simply cap off burners (4kW model) or use the handy selector switches (10kW).
Each unit is complete with an electronic solenoid assembly - you can turn off CO2 generation at set times (with no gas leaks!).
- 4kW: 90m2 coverage, 10kW: 220m2 coverage
- Runs on liquid propane gas (LPG)
- Can modify CO2 output!
Why Add CO2?
Plants use CO2 for photosynthesis (sugar production).
If CO2 is restricted, so is sugar production.
Plants can handle 1000ppm - 1200ppm of CO2. There's only around 400ppm - 450ppm in the air. Bringing that up to the optimum 1200ppm is one of the easiest ways to increases your yield by up to 20%!
In summer, extra CO2 and also helps plants with heat stress by photosynthesising more!
Kit Contains
- Gas regulator
- 3.66m hose
- Hanging hardware
- Metal feed
- 24V power adapter
How To Use
- Connect the gas line
- Connect to your CO2 controller
- Full instructions are included.
- If capping off CO2 burners, always choose burners furthest from the igniter.
- Place an air circulator fan next to your generator to spread CO2 evenly in your room.
- Don't forget to keep the generator away from exhaust fans so - otherwise, an CO2 will be sucked right back out of your grow room.
Equipment needed (LPG) |
---|
1. Propane canister (red / orange) - available in most petrol stations or garages 2. LPG Generator (Pro-Leaf) 3. UK Propane Regulator (Low Pressure) - should come with the canister
4. CO2 Controller with inbuilt sensor / analyser (e.g. Pro-Leaf & 2-3 Pin Plug Adaptor) OR CO2 Controller and separate sensor/analyser (e.g. Evolution Controller & Evolution Analyser) 5. Pipe cutters 6. Leak detection fluid 7. Hose clamp / gas hose clips |
The Tech
4kW | 10kW | ||||
4 burners | 10 burners | 2 burners | 5 burners | 7 burners | |
Operating Pressure | 11.0" WC / 2.8 kPa | ||||
kW Rating | 2.65 | 6.65 | 1.35 | 3.30 | 4.65 |
BTU Rating | 9052 | 22630 | 4526 | 11315 | 15841 |
CO2 Output p/H (SCF) | 10.60 | 26.50 | 5.30 | 13.25 | 18.55 |
CO2 Output p/H (m3) | 0.30 | 0.75 | 0.15 | 0.38 | 0.53 |
Weight | 10kg | 11.60kg | |||
Dimensions (mm) | 380mm x 250mm x 510mm | ||||
Coverage (approx) m3 |
115m3 | 285m3 | 60m3 | 140m3 | 200m3 |
4kW | 10kW | ||||
4 burners | 10 burners | 2 burners | 5 burners | 7 burners | |
Operating Pressure | 4.50" WC / 1.15 kPa | ||||
kW Rating | 3.25 | 8.10 | 1.60 | 4.05 | 5.65 |
BTU Rating | 9052 | 27670 | 5534 | 13835 | 19369 |
CO2 Output p/H (SCF) | 10.80 | 27.70 | 5.30 | 13.25 | 18.55 |
CO2 Output p/H (m3) | 0.31 | 0.78 | 0.15 | 0.38 | 0.54 |
Weight | 10kg | 11.60kg | |||
Dimensions (mm) | 380mm x 250mm x 510mm | ||||
Coverage (approx) m3 |
115m3 | 285m3 | 60m3 | 140m3 | 200m3 |
Questions & Answers
Have a Question?
Be the first to ask a question about this.