Check stock in your local store

FREE UK Delivery Over £99

Spread The Cost - Pay in 3

Best Price Guarantee

Fuss Free Returns

Systemair RVK Extractor Fans

Only 3 left
SKU: 91362
Regular price £74.99
Regular price £79.99 Sale price £74.99 -6%
Size
Flow Rate

RVK Grow Room Fans

Systemair RVK Fans no longer need to be wired up - you just require a separate IEC Lead & Plug

Climate control can be easy and affordable – the German made RVK Systemair Extractor Fans see to that.

They’re robust, powerful and quiet, yet extremely low cost. You’ll connect and install them in no time at all. It’s no wonder they’re our bestselling fan!

Believe us, they will not let you down. They’ve been tried and tested time and time again – they’re virtually indestructible with airtight casing! Yours will safely run for 24 hours a day without stopping

You won’t find a fan this good for such a low cost anywhere else. It’s an absolute must for entry-level growers! Experienced growers still swear by them.

  • Designed to run 24/7
  • Easily connects to carbon filters and silencers
  • It’s a bestseller!
  • Systemair – a trusted brand
  • Quiet with low vibration
  • Maintenance-free and highly reliable
  • Ideal as an extractor fan and intake fan
  • Speed-controllable
  • Integral thermal contacts
  • Flexible! Can be installed in any position
  • Mounting bracket included

Try A Complete Kit

To make life easy, opt for a Professional Extraction Kit - you get an RVK Extractor Fan, a CarboAir 50 Carbon Filter, 5m Power Cable, 5m Combi Ducting, a Fast Clamp and a Quick Release Duct Clip.

You Will Also Need

Choosing Your Fan

  • Use one fan to draw air out of your grow room
  • Use air vents or a second, smaller RVK extractor fan to draw air in

Please see ‘The Tech’ to work out which size fans you need.

Choosing A Carbon Filter

To remove foul odours, you need to use a carbon filter with your extractor fan. Make sure your carbon filter’s spigot/flange size is the same as that in your extractor fan. Here are the carbon filters compatible with each fan:

100mm (4") RVK100 A1 Extractor Fan - 184m3/hour: CarboAir 50 100/330
125mm (5") RVK125 A1 Extractor Fan - 220m3/hour: CarboAir 50 125/330
150mm (6") RVK150 A1 Extractor Fan - 430m3/hour: CarboAir 50 150/330
150mm (6") RVK150 L1 Extractor Fan - 720m3/hour: CarboAir 50 150/660
200mm (8") RVK200 A1 Extractor Fan - 796m3/hour: CarboAir 50 200/660
250mm (10") RVK250 L1 Extractor Fan - 1134m3/hour: CarboAir 50 250/660
315mm (12.5") RVK315 A1 Extractor Fan - 1362m3/hour: CarboAir 50 315/660

The Tech

100mm (4") RVK100 A1 Extractor Fan - 184m3/hour

• Max. airflow: 184m3/h
• Flange size: 99mm
• Max power consumption: 29W
• Sound pressure level at 3 m: 34.5 dB(A)
• Voltage: 230V
• Frequency: 50Hz
• Phase: 1~
• Input power: (P1) 29.1 W
• Current: 0.171 A
• R.p.m: 2482
• Weight: 1.8kg
• Max. temperature of transported air: 70°C
• Max. temperature of transported air when speed-controlled: 70°C
• Insulation class: B
• Enclosure class, motor: IP44

125mm (5") RVK125 A1 Extractor Fan - 220m3/hour

• Max. airflow: 220 m3/h
• Flange size: 124mm
• Max power consumption: 29W
• Sound pressure level at 3m: 37.5 dB(A)
• Voltage: 230V
• Frequency: 50Hz
• Phase: 1 ~
• Input power (P1): 29.2W
• Current: 0.172 A
• R.p.m: 2469
• Weight: 1.8kg
• Max. temperature of transported air 70°C
• Max. temperature of transported air when speed-controlled 70°C
• Insulation class: B
• Insulation class: B
• Enclosure class, motor :IP44

150mm (6") RVK150 A1 Extractor Fan - 430m3/hour

• Max. airflow: 430 m3/h
• Flange size: 149mm
• Max power consumption: 60W
• Sound pressure level at 3m: 40.6 dB(A)
• Voltage: 230V
• Frequency: 50 Hz
• Phase: 1 ~
• Input power (P1): 59.6W
• Current: 0.262 A
• R.p.m.: 2437
• Capacitor: 2 µF
• Weight: 2.7kg
• Max. temperature of transported air: 70°C
• Max. temperature of transported air when speed-controlled: 70°C
• Insulation class: B
• Enclosure class, motor: IP44

150mm (6") RVK150 L1 Extractor Fan - 720m3/hour

• Max. airflow: 720m3/h
• Flange size: 149mm
• Max power consumption: 109W
• Sound pressure level at 3 m: 44.8 dB(A)
• Voltage: 230V
• Frequency: 50 Hz
• Phase: 1 ~
• Input power (P1): 109W
• Current: 0.48 A
• R.p.m.: 2527
• Capacitor: 3 µF
• Weight : 3.2kg
• Max. temperature of transported air: 70°C
• Max. temperature of transported air when speed-controlled: 70°C
• Insulation class: F
• Enclosure class, motor: IP44 IP
• Energy class, basic unit: E
• Energy class, basic unit option: C
• ErP ready: ErP 2016/ErP 2018

200mm (8") RVK200 A1 Extractor Fan - 796m3/hour

• Max. airflow: 796 m3/h
• Flange size: 199mm
• Max power consumption: 104W
• Sound pressure level at 3 m: 42 dB(A)
• Voltage: 230V
• Frequency: 50 Hz
• Phase: 1 ~
• Input power (P1): 104W
• Current: 0.46 A
• R.p.m.: 2495
• Capacitor: 3 µF
• Weight : 3.3kg
• Max. temperature of transported air: 70°C
• Max. temperature of transported air when speed-controlled: 70°C
• Insulation class: F
• Enclosure class, motor: IP44
• Energy class, basic unit: E
• Energy class, basic unit option: B
• ErP ready: ErP 2016/ErP 2018

250mm (10") RVK250 L1 Extractor Fan - 1134m3/hour

• Max. airflow: 1134 m3/h
• Flange size: 249mm
• Max power consumption: 159W
• Sound pressure level at 3 m: 41.9 dB(A)
• Voltage: 230V
• Frequency: 50 Hz
• Phase: 1 ~
• Input power (P1): 159 W
• Current: 0.691 A
• R.p.m: 2531
• Capacitor: 4 µF
• Weight: 3.9kg
• Max. temperature of transported air: 70°C
• Max. temperature of transported air when speed-controlled: 70°C
• Insulation class: F
• Enclosure class, motor: IP44 IP
• Energy class, basic unit: E
• Energy class, basic unit option: B
• ErP ready: ErP 2016/ErP 2018

315mm (12.5") RVK315 A1 Extractor Fan - 1362m3/hour

• Max. airflow: 1362 m3/h
• Flange size: 314mm
• Max power consumption: 222W
• Sound pressure level at 3 m: 45 dB(A)
• Voltage: 230V
• Frequency: 50 Hz
• Phase: 1 ~
• Input power (P1): 222W
• Current: 0.971 A
• R.p.m.: 2696
• Capacitor: 5 µF
• Weight : 5.2 kg
• Max. temperature of transported air: 70°C
• Max. temperature of transported air when speed-controlled: 70°C
• Insulation class: B
• Enclosure class, motor: IP44 IP
• ErP ready: ErP 2018/ErP 2016

How to Use

Connect a Power Lead to the Fan

The fan comes with an IEC connection, you will need to use a power cable to connect it to power. Buy 5m IEC plug & Lead separately here.

Identify the Direction of Air Flow
Air needs to travel out of your growing area for extraction, or into your growing area for intake. There’s an arrow on the fan’s case to show you which way the air travels.

Connecting up the Equipment
Attach a suitable length of ducting to the exhaust side of the fan, using a duct clip and then feed the ducting through the duct port in your tent, or to the area you wish to vent to.

Attach the other end of the fan to your filter using a fast clamp or small piece of ducting and a duct clip.

Hanging the Extraction System
It can be difficult getting the system into position on your own, but not impossible – we recommend using rope ratchets.

Fuss Free Returns

Any issues we'll help you out.

Payments shown as GWHP

Discreet and secure

Lightning Fast Delivery

Get growing faster

Plain Packaged Deliveries

Always unbranded boxes

local grow shop growell hydroponics

YOUR LOCAL HYDROPONICS EXPERT

Visit Your Local GroWell Shop

We won't be beaten on price or advice.

Covering the Midlands, Bristol and London, whichever of our shops you visit, we can guarantee you'll get the best price and unbeatable advice from our expert staff.

Find Your Local GroWell